JNNP

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Klostermann, F
Right arrow Articles by Curio, G
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Klostermann, F
Right arrow Articles by Curio, G
Journal of Neurology Neurosurgery and Psychiatry 2003;74:1031-1035
© 2003 BMJ Publishing Group


PAPER

Identification of target areas for deep brain stimulation in human basal ganglia substructures based on median nerve sensory evoked potential criteria

F Klostermann1, J Vesper2, G Curio1

1 Neurophysics Group, Department of Neurology, Klinikum Benjamin Franklin, Freie Universität, Berlin, Germany
2 Department of Neurosurgery, Freie Universität, Berlin

Correspondence to:
Correspondence to:
Dr F Klostermann, Neurophysics Group, Department of Neurology, Universitätsklinikum Benjamin Franklin, Freie Universität Berlin, Hindenburgdamm 30, 12200 Berlin, Germany;
fkloster{at}zedat.fu-berlin.de

Objective: In the interventional treatment of movement disorders, the thalamic ventral intermediate nucleus (VIM) and the subthalamic nucleus (STN) are the most relevant electrode targets for deep brain stimulation (DBS). This study tested the value of somatosensory evoked potentials (SEP) for the functional identification of VIM and STN.

Methods: Median nerve SEP were recorded from the final stimulation electrodes targeted at STN and VIM. Throughout the stereotactic procedure SEP were recorded during short electrode stops above STN/VIM and within the presumed target areas. After digital filtering, high and low frequency SEP components were analysed separately to parameterise both the 1000 Hz SEP burst and low frequency (<100 Hz) components.

Results: SEP recorded in the VIM target region could unequivocally be distinguished from SEP recorded in STN. The 1000 Hz burst signal was significantly larger in VIM than in STN without any overlap of amplitude values. In the low frequency band, a primary high amplitude negativity was obtained in VIM, contrasting with a low amplitude positivity in STN. SEP waveshapes in recordings above target positions resembled SEP obtained in STN. When entering VIM, a sharp amplitude increase was observed over a few millimetres only.

Conclusions: Based on SEP criteria, the VIM target but not the STN region can be identified by typical SEP configuration changes, when penetrating the target zone. The approach is independent of the patient’s cooperation and vigilance and therefore feasible in general anaesthesia. It provides an easy, reliable, and robust tool for the final assessment of electrode positions at the last instance during electrode implantation when eventual electrode revisions can easily be performed.


Keywords: sensory evoked potential; deep brain stimulation

Abbreviations: VIM, ventral intermediate nucleus; STN, subthalamic nucleus; DBS, deep brain stimulation; SEP, sensory evoked potential