Transcranial Doppler ultrasound

  1. HUGH S MARKUS
  1. Department of Clinical Neurosciences, King’s College School of Medicine and Dentistry and the Institute of Psychiatry
  1. Dr Hugh Markus, Department of Clinical Neurosciences, Institute of Psychiatry, De Crespigny Park, London SE5 8AF, UK. Telephone 0044 171 3465174; fax 0044 171 3465186; emailh.markus{at}iop.bpmf.ac.uk.

    The use of Doppler ultrasound to estimate blood flow velocity was described in 19601 but it was only in the 1980s that it was appreciated that sufficient ultrasound would pass through the skull to allow the detection of blood flow within the intracranial circulation.2 To achieve sufficient bone penetration low frequency ultrasound is used; 2 MHz is conventional. This increases tissue penetration at the cost of poor spatial resolution. Therefore, even with more recent transcranial duplex scanners two dimensional B mode images are of low spatial resolution, and in adults the technique primarily provides useful information about blood flow velocity. Using various bone windows, where the barrier to the ultrasound is thinnest, it is possible to insonate the proximal middle, anterior, and posterior cerebral arteries, the distal internal carotid artery, and the intracranial vertebrobasilar system.3 Localisation is achieved by the use of pulsed Doppler ultrasound allowing determination of the depth of the insonated vessel. Recent colour flow duplex systems, which can display the Doppler information from a number of vessels simultaneously, improve the ease with which the intracranial vessels can be identified. They also allow angle correction and therefore more accurate blood velocity measurements.

    Transcranial Doppler has a number of advantages as a method of evaluating cerebral haemodynamics. It is relatively cheap and non-invasive, allowing repeated measurements and continuous monitoring. It has a high temporal resolution making it ideal to study rapid changes in cerebral haemodynamics. On the negative side it relies on a trained technician, and in about 5%-10% of cases sufficient ultrasound cannot be transmitted through the skull to obtain a signal. In such cases the use of intravenous contrast agents, which contain stabilised microbubbles which pass into the arterial circulation and result in increased backscattering of ultrasound, may enable vessel identification.4 It should …

    Register for free content

    The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

    Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

    BMJ Careers - Latest neurology and neurosurgery jobs