Article Text

Download PDFPDF
Head injury outcome prediction in the emergency department: a role for protein S-100B?
  1. W J Townend1,
  2. M J Guy2,
  3. M A Pani4,
  4. B Martin3,
  5. D W Yates3
  1. 1Emergency Department, Hope University Hospital, Salford, UK
  2. 2Biochemistry Department, Hope University Hospital
  3. 3Emergency Department, Hope University Hospital
  4. 4Department of Internal Medicine, University Hospital, Frankfurt-am-Main, Germany
  1. Correspondence to:
 Dr W Townend, Emergency Department, Hope University Hospital, Salford M6 8HD, UK;
 wtownend{at}fs1.ho.man.ac.uk

Abstract

Background: Biochemical markers released after head injury may reflect the degree of brain damage, which is related to subsequent disability. If the serum level of a marker were found to be related to outcome, then earlier identification and intervention would be possible.

Objective: To investigate the potential of the serum marker S-100B protein to predict the outcome after head injury.

Methods: Blood samples for S-100B concentrations were taken from 148 adults within six hours of a head injury (initial Glasgow coma score 4–15). Patients were recruited from the emergency departments of four hospitals in Greater Manchester, United Kingdom. Outcome was assessed in 119 patients (80%) at one month using the extended Glasgow outcome scale (GOSE).

Results: A significant inverse correlation between serum S-100B level and GOSE was found (Spearman’s ρ = −0.349, p < 0.0001). A serum S-100B concentration of > 0.32 μg/l predicted severe disability (GOSE < 5) at one month with a sensitivity of 93% (95% confidence interval 68% to 100%), a specificity of 72% (54% to 79%), and a negative predictive value of 99% (93% to 100%).

Conclusion: Serum S-100B concentration can be used in the emergency department to identify patients with head injury who are most likely to have a poor outcome at one month.

  • head injury
  • outcome prediction
  • S-100B protein

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Competing interests: S-100B assay kits were provided at a reduced cost and the luminometer on which the assays were performed was supplied free of charge by Cambridge Life Sciences for the duration of the study. Byk-Sangtec Diagnostica are part sponsoring a further study in the Academic Department of Emergency Medicine, Hope Hospital.