Evaluation of a regional oxygen saturation catheter for monitoring SJVO2 in head injured patients

  • Original Articles
  • Published:
Journal of Clinical Monitoring Aims and scope Submit manuscript

Abstract

Objectives. Monitoring jugular venous oxygen saturation (SjvO2) has been useful for the early identification and treatment of cerebral ischemia in patients with severe head injury. However, the catheters that have been used for this purpose have not performed optimally. The purpose of this study was to evaluate the performance of a new regional oxygen saturation catheter for monitoring SjvO2.Methods. Eighteen regional oxygen saturation catheters, 4-Fr in diameter (Baxter Healthcare Corporation, Edward Critical Care), were used in this study. Each catheter was inserted percutaneously into the dominant jugular vein and the catheter's tip position in the jugular bulb was verified by radiograph. The catheter was calibratedin vitro prior to insertion using the optic calibrator provided by the manufacturer. The catheter was recalibrated every 8 to 12 hours by comparing the oxygen saturation value from the catheter with that measured by a cooximeter in a blood sample drawn through the catheter.Results.In vitro calibration using the optic calibrator was not always successful. Five catheters could not be calibrated. The remaining 13 catheters could all be calibrated, but only 9 provided a value that was within 4% of the oxygen saturation derived from the blond sample. After the firstin vivo calibration, the correlation between the catheter and the blond sample values was improved. A total of 196 comparisons were made. The median, 25th, and 75th quartile differences between the catheter and the blond sample measurement of SjvO2 were 0.00, −1.15, and 1.25%, respectively. Using longitudinal data regression, the overall slope of the regression between the catheter and blood values was 0.997 (p = 0.001).Conclusions. The new regional oxygen saturation catheter provided reliable measurement of SjvO2 83% of the time when the signal quality index was ≤3, and may be useful for continuous monitoring of SjvO2.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Gopinath SP, Robertson CS, Contant CF, Hayes C, Feldman Z, Narayan RK, Grossman RG. Jugular venous desaturation and outcome after head injury. J Neurol Neurosurg Psych 1994; 57: 717–723

    CAS  Google Scholar 

  2. Chan KH, Miller JD, Dearden NM, Andrews PJ, Midgley S. The effect of changes in cerebral perfusion pressure upon middle cerebral artery blood flow velocity and jugular bulb venous oxygen saturation after severe brain injury. J Neurosurg 1992; 77: 55–61

    Article  PubMed  CAS  Google Scholar 

  3. Cruz J. Combined continuous monitoring of systemic and cerebral oxygenation in acute brain injury: Preliminary observations. Crit Care Med 1993; 21: 1225–1232

    Article  PubMed  CAS  Google Scholar 

  4. Laird NM, Ware JH. Random-effects models for longitudinal data. Biometrics 1982; 38: 963–975

    Article  PubMed  CAS  Google Scholar 

  5. Jakobsen M, Enevoldsen E. Retrograde catheterization of the right internal jugular vein for serial measurements of cerebral venous oxygen content. J Cereb Blood Flow Metab 1989; 9: 717–720.

    PubMed  CAS  Google Scholar 

  6. Andrews PJD, Dearden NM, Miller JD. Jugular bulb cannulation: Description of a cannulation technique and validation of a new continuous monitor. Br J Anaesth 1991; 67: 553–558

    Article  PubMed  CAS  Google Scholar 

  7. Fortune JB, Feustel PJ, Weigle CGM, Popp JA. Continuons measuremen of jugular venons oxygen saturation in response to transient elevations of blood pressure in head-injured patients. J Neurosurg 1994; 80: 461–468

    PubMed  CAS  Google Scholar 

  8. Sheinberg M, Kanter MJ, Robertson CS, Contant CF, Narayan RK, Grossman RG. Continuons monitoring of jugular venous oxygen saturation in head-injured patients. J Neurosurg 1992; 76: 212–217

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

This work was supported by NIH grant #PO1-NS26716.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ritter, A.M., Gopinath, S.P., Contant, C. et al. Evaluation of a regional oxygen saturation catheter for monitoring SJVO2 in head injured patients. J Clin Monitor Comput 12, 285–291 (1996). https://doi.org/10.1007/BF02221748

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02221748

Key words

Navigation