Intracranial pressure, conductance to cerebrospinal fluid outflow, and cerebral blood flow in patients with benign intracranial hypertension (pseudotumor cerebri)

Ann Neurol. 1985 Feb;17(2):158-62. doi: 10.1002/ana.410170209.

Abstract

Intracranial pressure, conductance to cerebrospinal fluid outflow, and cerebral blood flow were investigated in 14 patients with benign intracranial hypertension (pseudotumor cerebri). Intracranial pressure was increased in 9 patients (20 to 30 mm Hg), borderline in 4 patients (15 to 18 mm Hg), and normal in 1 patient (8 mm Hg). Six patients had plateau waves, and all had B waves in more than 50% of the monitored time. Conductance to cerebrospinal fluid outflow, measured by a lumbo-lumbar perfusion method, was significantly reduced: 0.042 ml X mm Hg-1 X min-1 (+/- 0.004 [SEM]; normal, more than 0.080 ml X mm Hg-1 X min-1). Cerebral blood flow was measured by xenon 133 inhalation and single photon emission computer tomography. Mean hemispheric flow was normal in all cases, averaging 59 +/- 9 ml X 100 gm-1 X min-1. Only 2 patients showed focal low-flow areas. Thus, a disturbance of cerebrospinal fluid circulation seems to be of pathogenetic significance in benign intracranial hypertension.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Cerebrospinal Fluid / physiology*
  • Cerebrovascular Circulation*
  • Child
  • Female
  • Humans
  • Intracranial Pressure
  • Male
  • Middle Aged
  • Pseudotumor Cerebri / diagnostic imaging
  • Pseudotumor Cerebri / physiopathology*
  • Radiography
  • Tomography, Emission-Computed
  • Xenon Radioisotopes

Substances

  • Xenon Radioisotopes