Table 1

Measurement reproducibility for the different subgroups

VariableMean (mm2)Within subject SD95% reference range*CV (%)Reliability coefficient (95% CI)†
*1.96 × within subject SD; 95% of measurements are expected to lie within this departure from the true value.
†The proportion of total variance caused by between subject variation. Under assumptions which are plausible here, one minus this value is the proportion of variation caused by measurement error.
CV, coefficient of variation.
Acute diseased nerve area18.41.13± 2.216.40.92 (0.88 to 0.96)
Acute healthy nerve area17.81.21± 2.376.80.89 (0.84 to 0.94)
Six month diseased nerve area16.40.76± 1.494.60.96 (0.95 to 0.98)
Six month healthy nerve area17.41.11± 2.186.40.91 (0.87 to 0.95)