TableĀ 2

Assays

Assay numberAssayIsoformTransfection[Serum]DetectionQuantitative
1Live CBAM23Transient1:20FluorescenceSemi
2Live CBAM23Transient1:20FluorescenceSemi
3Live CBAM23Transient1:20FluorescenceSemi
4Fixed CBA EIM23Transient1:10FluorescenceSemi
5Fixed CBA EIM1Transient1:10FluorescenceSemi
6Fixed CBA EIM1Transient1:10FluorescenceSemi
7Fixed CBA EOM1Transient1:10FluorescenceSemi
8Fixed CBA EOM1Transient1:10FluorescenceSemi
9Fixed CBA EOM1Transient1:10FluorescenceSemi
10Fixed CBA EOM1Transient1:10FluorescenceSemi
11Fixed CBA EOM1Transient1:60FluorescenceSemi
12Fixed CBA EOM1Transient1:10FluorescenceSemi
13Fixed CBA EOM1Transient1:10FluorescenceSemi
14FACSM23Transient1:20FluorescenceYes
15FACSM23Stable1:100FluorescenceYes
16FACSM23Transient1:50FluorescenceYes
17FACSM1Stable1:100FluorescenceYes
18TBA-IHC-ratNANA1:200ColorimetricSemi
19TBA-IIF-rat/monkeyNANA1:10FluorescenceSemi
20TBA-IIF-mouseNANA1:60FluorescenceSemi
21ELISAM23NA2:3ColorimetricYes
  • The basic characteristics of each assay are presented in six columns.

  • FACS, flow cytometry; Fixed CBA EI, fixed cell-based assay done in-house at Euroimmun AG; Fixed CBA EO, fixed cell-based assay (Euroimmun AG commercial assay) run at different European diagnostic centres; Live CBA, live cell-based assay; NA, not applicable; TBA-IHC, indirect immunohistochemistry on tissue sections; TBA-IIF, indirect immunofluorescence on tissue sections.