Skip to main content
Log in

Multiple sclerosis: interobserver agreement in reporting active lesions on serial brain MRI using conventional spin echo, fast spin echo, fast fluid-attenuated inversion recovery and post-contrast T1-weighted images

  • Original Communication
  • Published:
Journal of Neurology Aims and scope Submit manuscript

Abstract

Previous studies have addressed the question of the precision in assessing multiple sclerosis (MS) activity by counting enhancing lesions on gadolinium enhanced brain magnetic resonance imaging (MRI). However, counting the active lesions on serial unenhanced MRI obtained by various pulse sequences has not been yet considered. We compared the interobserver levels of agreement in reporting active MS lesions on serial enhanced and unenhanced MRI to assess whether the use of various unenhanced techniques may change the degree of interobserver measurement reproducibility. Dual-echo conventional spin echo (CSE), dual-echo fast spin echo (FSE), fast fluid-attenuated inversion recovery (FLAIR) and Gd-enhanced T1-weighted brain MRI were obtained from five MS patients at baseline and monthly for 2 months. Six experienced observers independently identified and counted active MS lesions on the two follow-up MRI scans. Active lesions were considered to be all the enhancing lesions and any new or enlarging lesion on enhanced and unenhanced scans. Interobserver levels of agreement were calculated by weighted κ values. Very good agreement was reached only for counting total and new Gd-enhancing lesions. Good agreement was achieved for counting new lesions on the three unenhanced techniques, whereas the agreement for counting enlarging lesions was poor with all the MRI techniques. The level of agreement was significantly heterogeneous for various MRI techniques but not for various lesion sites. These results confirm that counting enhancing lesions is the most reliable method for assessing MS activity, but the use of any of the available unenhanced MRI techniques did not result in different levels of interobserver agreement when reporting new and enlarging MS lesions on serial scans.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 10 December 1998 Received in revised form: 6 April 1999 Accepted: 26 April 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Rovaris, M., Barkhof, F., Bastianello, S. et al. Multiple sclerosis: interobserver agreement in reporting active lesions on serial brain MRI using conventional spin echo, fast spin echo, fast fluid-attenuated inversion recovery and post-contrast T1-weighted images. J Neurol 246, 920–925 (1999). https://doi.org/10.1007/s004150050483

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004150050483

Navigation